DATAMATH CALCULATOR MUSEUM |
Lloyd's Accumatic 30 (Model EH-9036, Type 255C)
Date of introduction: | July 1974 | Display technology: | Fluorescent |
New price: | Display size: | 8 | |
Size: | 5.8" x 3.5" x 1.25" 147 x 89 x 32 mm3 |
||
Weight: | 5.8 ounces, 164 grams | Serial No: | 2-09442 |
Batteries: | 4*AA | Date of manufacture: | mth 02 year 1975 |
AC-Adapter: | YA-7247 (120V AC), YA-7585 240V AC) | Origin of manufacture: | Japan |
Precision: | 8 | Integrated circuits: | Hitachi HD3633 |
Logic: | Chain | Displays: | Futaba 8-CT-02 |
Memories: | |||
Program steps: | Courtesy of: | Joerg Woerner |
The
Accumatic 30 calculator sold by Lloyd's Electronics, Inc.,
Compton, California caught our attention when we were looking into the first
single-chip calculator circuits manufactured by Sharp Electronics Corporation in
Japan, just to discover that this model number was used between 1974 and 1976
with at least 12 different calculator
designs sporting 4 different
calculator brains.
Dismantling the featured Lloyd's Accumatic 30 (EH-9036, Type
255C) calculator assembled by an unknown Original
Equipment Manufacturer (OEM) in February 1975 in Japan reveals a very compact
design based on a single-sided printed circuit board (PCB) for the main
electronics, a single-sided PCB for the keyboard and powered by four disposable
1.5 Volts batteries or an external power adapter.
The
Main-PCB is centered around a HD3633 single-chip calculator circuit manufactured
by Hitachi and the few other remaining components on the PCB are mainly used to
generate the different supply voltages for the HD3633 and Vacuum Fluorescent
Display (VFD) and to bias the anodes and grids of the display with respect to
its filament.
To gain some knowledge about the differences
between the various single-chip calculator circuits used with the Lloyd's
Accumatic 30, we decided here at the Datamath Calculator Museum to give the featured calculator
a full "Teardown Treatment" and share our findings accordingly.
Calculating Unit:
The HD3633 located in the featured calculator seems to be one of the first
single-chip calculator circuits designed by Hitachi. It features an integrated
clock oscillator and both its segment and digit output drivers are interfacing
directly with low-voltage VFDs up to 35 Volts.
Display:
The featured Lloyd's Accumatic 30 calculator manufactured in February 1975 makes
use of an 8-Digit low-voltage VFD manufactured by Futaba and known as Type
8-CT-02. The display is soldered with its 18 wires directly to the Main-PCB. A
small red LED with long leads is soldered directly onto the Main-PCB of the Accumatic
30 calculator to act as Minus "dot" for 8-digit numbers.
Display Driver: The term "low-voltage" Vacuum Fluorescent Display might
be misleading when used together with a calculator powered by four 1.5 Volt
batteries. Common VFDs used with portable electronic calculators are usually
operated around 30 Volts, significantly higher than the 10 to 15 Volts operating
voltage of single-chip calculator circuits used in the 1970s. While the first
generation of Texas Instruments TMS0100 single-chip calculator circuits lacked
any display drivers and left the choice of display technology to their
customers, focused the second generation products mainly on Light-Emitting Diode
(LED) technology. In or around 1974, most Western calculator designs still
relied on rather expensive LED technology but Japanese companies like Casio,
Sanyo, Sharp and Toshiba started to leverage the lower manufacturing costs of
VFDs, instead. Texas Instruments introduced in 1974 consequently with the
TMS0850 their first product series focused on battery operated VFD calculators
and modified the integrated segment and digit output drivers to withstand up to
-35 Volts. Hitachi on the other hand entered the marked of single-chip calculator
circuits in 1973 and focused immediately on compatibility with VFDs. The
HD3633 chips are manufactured in PMOS technology, meaning the
output transistors are "high-side" switching and the most positive voltage of
the chip is labeled VSS for 0 Volt, all other voltages in the
calculator are consequently negative with respect to VSS. Multiplexed
low-voltage VFDs need a voltage difference between its filament and the grids
and anodes of the numbers of around 30 Volts to light up and to avoid "ghosting"
while scanning, the deactivated grids and anodes should be slightly lower than
the filament voltage. An elegant and very common solution is found with this
Accumatic 30 calculator, too. The grids and anodes of the VFD are "pulled-down"
with 16 resistors (150k Ohm) to around -28 Volts, the filament is biased to
around -26 Volts (2.0k Ohm resistor) and the HD3633 switches the
relevant grids and anodes to around 0 Volt to lit them up.
Clock: The Lloyd's Accumatic 30 makes use of the internal clock
oscillator of the HD3633 Series of single-chip calculator circuit, we identified a
capacitor with
180 pF connected
between Pin 20 (CKO) and Pin 21 (CKI) of the HD3633, resulting in a clock frequency of about
87 kHz.
Power Supply: The Lloyd's Accumatic 30 calculator is powered with
four disposable AA-sized 1.5 Volt batteries or an external 6 Volt power adapter and uses a
complex DC/DC converter to
generate a total of four voltages:
• VDD - Negative supply for
HD3633 (-7.0 V) • VGG - Negative supply for HD3633 (-14.6 V) • VPP - Negative supply for VFD anodes and grids (-27.8 V) • VFIL - AC supply for VFD Filament (2.5 V) |
We measured the operating current of the featured Lloyd's Accumatic 30 calculator for three different cases:
Mode | Display | Current VBAT = 6.0 V |
Clock Frequency |
Calculating | 0. | 34 mA | 87 kHz |
Calculating | 88888888. | 52 mA | 87 kHz |
Calculating | 0. ⚫ | 42 mA | 87 kHz |
Calculating the power consumption at 6 Volts for the Lloyd's Accumatic 30 results in about 200 mW displaying a '0.' and about 310 mW with all segments but the minus sign illuminated. A very interesting result, a Canon LE-84 calculator with a LED display and using four disposable 1.5 Volt Alkaline batteries and a DC/DC converter for its TMS0801 chip clocks in at around 100 mW displaying a '0.' and 320 mW with all segments lit; showing both an advantage and disadvantage of LED-based calculators versus their VFD-based counterparts:
• LED: Only illuminated segments draw current - advantage LED while displaying
'0.' • VFD: Filament uses always current, segment currents are almost negligible - advantage VFD while displaying '88888888.' |
And yes, the little red LED used as Minus "dot" draws about 8 mA, as much as 22 segments of the VFD.
Keyboard: The keyboard assembly of the
Lloyd's Accumatic 30 was manufactured by GICO and uses 19 spring-supported
plastic keys pushing small fingers on stamped sheet-metal pieces against
contacts etched on a single-sided phenolic PCB.
While
most single-chip calculator circuits are using their digit driver outputs
to scan the keyboard matrix, decided Hitachi to provide with the HD3633 five
dedicated scanning outputs just for the keyboard. The [C] key is not included in
the scan-matrix but uses an individual contact instead. Please notice that the
featured keyboard module features 13 contacts, obviously a relict from the
original Accumatic 30, but is connected with only
11 pins (5 keyboard scan lines, 4 keyboard return lines, 2 contacts for the [C]
key) to the Main-PCB.
Here
at the Datamath Calculator Museum we use
the DCM-50A Platform to
Characterize and
Reverse-engineer
Single-chip Calculator Circuits. Many designs of electronic calculators do not
use all features of their calculator brains and it would be difficult to unleash
the full potential of the calculator chips in these cases. Additionally are
electronic calculators "closed systems" with limited flexibility to measure
signals, change voltages or clock frequencies, provide additional input keys or
even change the display technology or specifications additional digits. Core
idea of the DCM-50A is providing a generic platform to access all features of a
single-chip calculator circuit and with the
DCM-50A (PLAYGROUND) we
increased the scope from Texas Instruments products to offerings from their
competitors in the 1970s, namely AMI, Cal-Tex, Commodore/MOS Technology,
Electronic Arrays, General Instrument, Hitachi, Litronix, Matsushita, Mitsubishi, Mostek,
National Semiconductor, NEC, Omron, RFT, Rockwell, Sharp, Toshiba, and Western
Digital.
The Accumatic
30 sold by Lloyd's mid of the Seventies went through many redesigns within its
lifecycle of around 2 years and we started to look into the differences of the
four different single-chip calculator circuits located in at least 12 different
design iterations. Learn more about our observations
here.
If you have additions to the above article please email: joerg@datamath.org.
© Joerg Woerner, November 10, 2024. No reprints without written permission.